4NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN). It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.
18'' TFT color LCD, multi-language interface. 2Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3All-round monitor for adult, pediatric and neonate. 4With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
5Waveform, parameter color and location can be set optionally. 6Operation mode: keys and buttons. 7Display up to 8-channel waveform on one screen. 8Display 7-lead ECG waveform on one screen, and with ECG step function.
9Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 11NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
12Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 13Drug concentration calculation and titration table functions. 14Print trend table data with one-key.
15Connect to Central Monitoring System by 3G, WiFi or wired mode. 16AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 17Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary). Lead mode: 3-lead or 5-lead. Lead selection: I, II, III, aVR, aVL, aVF, V.
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV. Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s.Measurement and alarm range: 15350bpm. Accuracy: ±1% or ±1bpm, whichever is greater.
Alarm accuracy: ± 2 bpm. Measurement and alarm range: -2.0mV+2.0mV. Accuracy: -0.8mV+0.8mV ±0.04mv or ±10%, whichever is greater. Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC. Measurement and alarm range: 0150rpm. Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s.Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes. Measurement period in STAT mode: 5 minutes. Measurement and alarm range: 10 270 mmHg. Cuff pressure accuracy: ±3 mmHg. Maximal mean deviation: ±5 mmHg.
Measurement and alarm range: 0 100%. Measurement and alarm range: 30 250 bpm. Measurement accuracy: ±2 bpm or ±2%, whichever is greater. Measurement and alarm range: 0 50? Adult fingertip SpO2 probe (5-pin).
Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H). Food and Drug Administration and state and local regulatory agencies. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE, TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved.